Medical Injury due to Broken Catheters
Catheters that are not properly manufactured, are mishandled
during insertion or tunneling, are not replaced when needed, or are
incorrectly clamped, may fracture. Also, equipment used in conjunction
with catheters, such as high-pressure infusion/injection pumps, can
generate intra-catheter pressure significant enough to cause weakening
or fracture of the catheter.
1 Unfortunately, fracture is
a documented complication in all types of long-term venous-access catheters
- Hickman, Vygon Nutricath-S, Port-a-Cath, Broviac, Groshong. If a fracture
occurs a catheter fragment can embolize, following the circulatory system
to the pulmonary artery or the heart. If this happens, an operation
would be required to remove the fragment.
A common method of fracture is referred to as the 'Pinch-off Syndrome' in which the catheter is broken due to compression between the clavicle and the first rib. The compression causes wear on the catheter and can result in fracture, especially in patients needing a long-term catheter for venous access. The longer the catheter is in use, the higher the risk of fragmentation. Long-term venous access is often a necessity to chronically ill patients - delivering necessary antibiotics, nutritional support, and chemotherapy for patient care. Therefore, the danger from compression is two-fold: 1) potential fragmentation and embolism and 2) inability to deliver crucial medications or nutrients. However, careful placement of a catheter or review and replacement of a worn catheter could avoid these potential broken catheters.
For example, a malpositioned catheter passes through a smaller region of the space between the clavicle and first rib than does a properly positioned catheter. A catheter located in this areolar tissue is more susceptible to compression and fracture because it is more likely pinched by patient arm movement. A broken catheter could result in an embolism requiring an otherwise unnecessary medical procedure to remove the fragment. Depending on the size of the fragment and the location in the body, this procedure could be relatively simple or require major surgery. The preferred methods of emboli removal are by percutaneous extraction or non-surgical transvenous methods, such as using a snare to grab the catheter fragment. However, if this method is unsuccessful or impossible a major operation such as a thoracotomy is necessary.
Complications could also result from broken catheters such as:: fragments could cause a thrombosis, perforation of blood vessels, or bacterial infection. And if corrective action is not taken in time, serious injury, heart attack, or death could result. However, if a doctor inserts the catheter properly and monitors the status and placement of the catheter while inserted, harm is less likely to occur.
If you need a lawyer's assistance with a broken catheter
related injury please
contact us.
Additional Broken If you need assistance please
contact
our Medical Malpractice Lawyersinformation
Proposal for venous catheter DVT Modifications
Venous catheters are employed in cases of patients requiring long-term
intravenous treatment. While they offer substantial benefits, there
are potentially fatal risks associated with their use. One of these
risks involves the spontaneous fracture, Broken Catheter, and resulting
embolization (vessel occlusion), which are apparently caused by mechanical
deterioration in the body....
More
information on Broken Catheters
The tensile strength and elongation before failure
of six commonly used epidural catheters was investigated...
Broken Catheters
included in case studies
Lawyer obtains award for injury due to Broken Catheter. Reuse
of single use catheters Biomedical Safety Standards Editor. Catheter
for single use allegedly reused: broken tip leads to $970,000 award.
Biomed Safety Standards 1981;(July 15):77.
Broken
Catheter Case
Reuse of catheters can lead to several adverse consequences, including
broken catheters.
Broken
Catheters and other associated risks from Journal of Cardiology
Medical Risks of an
oxytocin infusion
with Epidural Anesthesia During Childbirth.
Epidural
anesthesia risk include Broken Catheters
Reuse of Disposable Medical Devices (Winter.1999/2000, Vol.25,
No.3) There were several articles in the L.A. Times raising concerns
about the lack of standards and the potential danger of this practice.
The articles discussed instances where the tips of cardiac catheters
had broken off in the hearts of patients and adverse patient reactions
to bacterial toxins resulting from devices that were not properly cleaned...
More
about broken catheters and other risks from the California Society
of Pathologists
If you need a lawyer's assistance with a broken catheter
please
contact
our Medical Malpractice Lawyers
1. The information on this page is accurate as of July 22, 2002.
2124 East Hanna Ave. Indianapolis, Indiana46227-3314
![]()
(800) 486-4450
(317) 780-6610
Fax: (317) 780-6620